Photometry vs. Radiometry: The Human Bias Trap
Understanding display safety requires distinguishing between two fundamental measurement domains:
- Photometry: Measures light as perceived by the human conscious visual cortex, weighted by the CIE curve peaking at 555 nm. The Fatal Flaw: A blinding 405 nm violet-blue laser has a photometric value near zero lumens because human eyes are insensitive to it—yet its photochemical retinal hazard is extreme!
- Radiometry: Measures pure electromagnetic energy in absolute physical units (Joules, Watts) regardless of human visual sensitivity.
The Master Unit: Spectral Radiance ()
The foundational metric for display emission is Spectral Radiance (), measuring radiant power () emitted per unit projected source area () into a solid angle (, measured in steradians) at wavelength :
By the Conservation of Radiance theorem, optical radiance at the screen surface is identical to the radiance entering your eye pupil! Knowing display spectral radiance and pupil diameter allows exact calculation of Retinal Irradiance ():
Blue Light Weighted Radiance ()
Under ISO/CIE 28002 standards, the total photochemical Blue Light Hazard is quantified by integrating spectral radiance against the ICNIRP weighting function :